GE F150 LED Flood

Report Number: ISO-NRCan 062

Issued: Nov/29/2012

Item tested GE F150 LED Flood
Rated electrical values 50/60Hz AC, 100-127V
Nominal CCT 4000
Item received date 19-Nov-2012
Test completed date 19-Nov-2012
Objecvie of test IES LM-79 was performed to measure the total luminous flux, Correlated colour temperature (CCT), colour rendering index (CRI), chromaticity coordinates (x,y), and spectral power distribution (SPD), and luminous efficacy (lm/W) .
Procedure With reference to Lumentra standard operation procedures Lumentra-SOP01.
Test report prepared by Rui Li, PhD
Engineering Consultant, Lumentra Inc.
Krishnan Harikumar, PhD
Senior Researcher, Lumentra Inc.
Test report approved by Venkat Venkataramanan, PhD
CTO, Lumentra Inc.

 

Test Conditions

Number of hours operated prior to measuremet 0
Total operating time of the product including stabilization 180 minutes
Stabilization time 180 minutes
Ambient temperature (°C) 25
Orientation of the product during testing Vertical Base-down
Photometric method used Sphere-spectroradiometer
Designation and type of reference standard used 75W Halogen lamp, SCL-1400-F106, omni-directional, NVLAP calibration traceable to NIST
Correction factors applied Self-absorption
Photometric measurement conditions 76 inch integrating sphere, 4p geometry
Spectroradiometer resolution 1.5 nm
Equipment used SLM-76-C SphereOptics integrating sphere system, Yokogawa WT230 Digital power meter
Deviation from standard operating procedures N/A

 

Test Results

Total luminous flux (Lumens) 6186
CIE Chromaticity coordinate x 0.3670
CIE Chromaticity coordinate y 0.3760
CIE Chromaticity coordinate u’ 0.2166
CIE Chromaticity coordinate v’ 0.4992
Duv 0.003838
Correlated colour temperature CCT (K) 4377
Colour rendering index (CRI) 76.64
Voltage RMS (V) 120.0
Current RMS (A) 0.741
Real Power (W) 86.7
Power Factor 0.975
Total Harmonic Distortion (%) 21.8
Efficacy (lm/W) 71.3

 

Manufacturer Claims

Total luminous flux (Lumens) N/A
Correlated colour temperature CCT (K) 4000
Colour rendering index (CRI) N/A
Voltage RMS (V) 100-127V
Power (W) 90
Efficacy (lm/W) N/A
Life (hour) 50,000
Equivalency N/A
   

 

Figure 1. Spectral Power Distribution

Figure 2. CIE Chromaticity Diagram

Figure 3. Picture of the item tested

This report is based on published industry procedures and the results relate only to the item tested. This report shall not be reproduced except in full, without written approval of Lumentra Inc.